Hydraulics

How to choose hydraulic hose size from flow rate

Choose hydraulic hose inner diameter from flow and fluid velocity, then confirm the standard size and application requirements with the hose maker's catalogue.

HELIVIQ Team · Published

Why size matters

A hose that is too small raises fluid velocity, which can cause heat, pressure drop and noise. A hose that is too large adds cost, weight and a bigger bend radius.

The formula

Imperial: D = √(0.4085 × Q ÷ V). D is hose ID in inches, Q is flow in US gpm, and V is velocity in ft/s.

Example: 10 gpm at 20 ft/s → D ≈ 0.452 in → nearest standard size up is ½ in (-8).

Metric: d (mm) = 4.607 × √(Q ÷ v). Q is flow in L/min and v is velocity in m/s. This is the same formula converted to metric units.

Example: 40 L/min on a pressure line at 4.6–6.1 m/s → d ≈ 11.8–13.6 mm → choose the nearest standard size up, e.g. ½ in / -8 (12.7 mm ID) at the higher velocity, or the next size up if you want lower velocity.

The same 40 L/min on a suction line at 0.6–1.2 m/s → d ≈ 26.6–37.6 mm.

choose the nearest standard size up and confirm with the hose maker's catalogue.

Recommended maximum velocities

Recommended maximum fluid velocities by line type
Line typeVelocity (ft/s)Velocity (m/s)
Suction / inlet2–40.6–1.2
Return10–153.0–4.6
Pressure, 500–2,000 psi15–204.6–6.1
Pressure, 3,000 psi25≈ 7.6

Nomograph method

Most hose catalogues include a flow/velocity nomograph. Draw a line from flow to velocity and read the hose ID in the centre column.

After size, check

  • Working pressure rating
  • Temperature range
  • Fluid compatibility
  • Minimum bend radius
  • Fitting ends