Why size matters
A hose that is too small raises fluid velocity, which can cause heat, pressure drop and noise. A hose that is too large adds cost, weight and a bigger bend radius.
The formula
Imperial: D = √(0.4085 × Q ÷ V). D is hose ID in inches, Q is flow in US gpm, and V is velocity in ft/s.
Example: 10 gpm at 20 ft/s → D ≈ 0.452 in → nearest standard size up is ½ in (-8).
Metric: d (mm) = 4.607 × √(Q ÷ v). Q is flow in L/min and v is velocity in m/s. This is the same formula converted to metric units.
Example: 40 L/min on a pressure line at 4.6–6.1 m/s → d ≈ 11.8–13.6 mm → choose the nearest standard size up, e.g. ½ in / -8 (12.7 mm ID) at the higher velocity, or the next size up if you want lower velocity.
The same 40 L/min on a suction line at 0.6–1.2 m/s → d ≈ 26.6–37.6 mm.
choose the nearest standard size up and confirm with the hose maker's catalogue.
Recommended maximum velocities
| Line type | Velocity (ft/s) | Velocity (m/s) |
|---|---|---|
| Suction / inlet | 2–4 | 0.6–1.2 |
| Return | 10–15 | 3.0–4.6 |
| Pressure, 500–2,000 psi | 15–20 | 4.6–6.1 |
| Pressure, 3,000 psi | 25 | ≈ 7.6 |
Nomograph method
Most hose catalogues include a flow/velocity nomograph. Draw a line from flow to velocity and read the hose ID in the centre column.
After size, check
- Working pressure rating
- Temperature range
- Fluid compatibility
- Minimum bend radius
- Fitting ends